• Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
  • Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
  • Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
  • Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
  • Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
  • Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump

Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump

Brand Replacement: Swep, Danfoss
Heat Pump Plate Heat Exchanger Material: Stainless Steel AISI 304, 316
Transport Package: Plywood Case
Specification: ISO9001, CE, UL, WRAS, ROHs and etc.
Trademark: Baode
Origin: China
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
BL210
HS Code
8419500090
Production Capacity
1000 PCS/Month

Product Description

Evaporator flow principle
The channels formed between the corrugated plates and corners are arranged so that the two media flow
Through alternate channels, always in opposite directions (counter current flow). The two phase refrigerant (vapor + liquid) enters the bottom left of the exchanger with a vapor quality depending on the operating condition of the plant. Evaporation of the liquid phase takes place inside the channels and some degrees of superheat are always requested, which is the reason why the process is called "dry expansion". In the enclosed evaporator picture the dark and light blue arrows show the location of the refrigerant connections. The water (brine) to be cooled flows counter current in the opposite channel; The dark and light red arrows show the location of the water (brine) connections.

Standard design
The plate pack is covered by cover plates. Connections are located in the front or rear cover plate. The channel plates are corrugated to improve heat transfer efficiency and to make them rigid.
Dual system
The real dual circuit patented by Baode in a solution with diagonal flow is obtained by means of pressed plates. The Brazed Plate Heat Exchanger can be connected with two independent refrigerant circuits. The special design ensures that each refrigerant circuit is in contact with the entire water flow. The main advantage is that at partial load (only one compressor running) water cooling is uniform and performance is maximized.
Standard materials
Cover plates: Stainless steel AISI 316
Connections: Stainless steel AISI 316
Plates: Stainless steel AISI 316
Brazing material: Copper

Particulars required for quotation
To enable Baode's representative to make a specific quotation, enquiries should be accompanied by the following particulars:
Flow rates or heat load required
Temperature program
Physical properties of liquids in question
Desired working pressure
Maximum permitted pressure drop

Short delivery time.
High quality
Reasonable price
Customer made
Know-how design and customer support
Model  BL210
Width, A [mm]  322
Height, B [mm]  739
Length, E [mm]  13+2.55n
 Horizontal port distance, C [mm]  205.2
 Vertical port distance, D [mm]  631
 Max pressure [Mpa]  3/4.5
Max flowrate [M3/h]  100
Weight [kg]  13+0.78n









 
Model BL14 BL20 BL26 BL26C BL50 BL95
Width, A [mm]  78 76 111 124 111 191
Height, B [mm]  206 310 310 304 525 616
Length, E [mm]  9+2.3n 9+2.3n 10+2.36n 13+2.4n 10+2.35n 11+2.35n
Horizontal port distance, C [mm] 42 42 50 70 50 92
Vertical port distance, D [mm]  172 282 250 250 466 519
Max pressure [Mpa]  3 3 3 3/4.5 3/4.5 3/4.5
Max flowrate [M3/h]  3.6 3.6 8.1 8.1 12.7 39
Weight [kg]  0.6+0.06n 1.0+0.08n 1.3+0.12n 2.2+0.16n 2.6+0.19n 7.8+0.36n

 

 
Model BL120 BL190 BL200 BL1400 BL100  * BL200  *
Width, A [mm] 246 307 321 429 248 322
Height, B [mm]  528 696 738 1398 495 739
Length, E [mm]  13+2.36n 13+2.75n 13+2.7n 22+2.78n 10+2.15n 13+2.55n
Horizontal port distance, C [mm] 174 179 188 220 157 205.2
Vertical port distance, D [mm] 456 567 603 1190 405 631
Max pressure [Mpa]  3 3 2.1 1.5 3/4.5 3/4.5
Max flowrate [M3/h]  42 100 100 300 42 100
Weight [kg]  7.2+0.52n 12.5+0.72n 13+0.75n 31.8+1.73n 6.5+0.37n 13+0.78n

Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
Equal AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat PumpEqual AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat PumpEqual AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat PumpEqual AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat PumpEqual AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat PumpEqual AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat PumpEqual AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat PumpEqual AC500 with Single and Double Refrigerant Circuit Copper Brazed Plate Heat Exchanger Evaporator for Heat Pump
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now