Plate heat exchanger Plates Features
? Equally distributing flow in the whole plate
? Improving its heat transfer efficiency
? Eliminating the fouling accumulation area
Features of Gasket Used in Plate Heat Exchanger
? Standard roof gasket.
? Protection groove of gasket: Gasket groove prevent the pads from being squeezed out and prolong its service time.
? Rubber gasket adopts latch-locked design, with observation holes for leakage.
? The fixed and seal functions are separate, even if there are some problems in fixed functions, its seal function can still work.
Standard Material
Material: 316L, 304, Ti, SMO, Hastelloy
Thickness: 0.5mm, 0.6mm
Gasket: NBR, EPDM
Gasket type: Clip on
|
BH60 |
BH100 |
BH150 |
BH200 |
Bh250 |
Exchange area. m2 |
0.15 |
0.24 |
0.62 |
0.85 |
1.5 |
Width. mm |
250 |
375 |
500 |
620 |
768 |
Height. mm |
750 |
875 |
1500 |
1740 |
2268 |
Connection diameter |
DN50 |
DN100 |
DN150 |
DN200 |
DN250 |
Tightening measure |
N(3.0+X) |
N(3.95+X) |
N(3.95+X) |
N(4.0+X) |
N(3.5+X) |
Thermal length |
D/X |
D/X |
D/X |
D/X |
D/X |
Working/Testing pressure,bar |
10/15| 16/21 |
10/15|16/21 |
10/15|16/21 |
10/15|16/21 |
10/15|16/21 |
Cross reference of ALFA LAVAL |
M6/M6M |
M10/M10M |
M15/M15M |
M20 |
MX25B |